4.5 Article Proceedings Paper

On evaluating x-ray imaging crystals with synchrotron radiation

Journal

REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 89, Issue 10, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.5045569

Keywords

-

Funding

  1. U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences [DE-AC02-06CH11357]

Ask authors/readers for more resources

Bent crystals used in diagnostics of plasmas combine x-rays diffracted from across the crystal. Therefore imperfections in the resulting 1-D spectrum or 2-D image are not the best way to find out why one particular crystal may differ in its performance from another and what, if anything, to do about it. Instead, here we want to measure the diffraction locally, with the necessary resolution. Nominally monochromatic and unidirectional radiation from the synchrotron's standard x-ray optics proved to be insufficient for the purpose. Here much better radiation comes from the x-ray topography setup at the x-ray optics testing beamline 1-BM at the Advanced Photon Source, thanks to a specially designed quartz conditioning crystal. Some worrisome features in a bent crystal's diffraction have thereby disappeared, while minor fabrication flaws remain highly visible. Published by AIP Publishing.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available