4.6 Article

All-optical crosstalk-free manipulation and readout of Chronos-expressing neurons

Journal

JOURNAL OF PHYSICS D-APPLIED PHYSICS
Volume 52, Issue 10, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/1361-6463/aaf944

Keywords

Chronos; calcium indicator; optogenetics; crosstalk; functional imaging; neuron; neuromodulation

Funding

  1. National Institutes of Health [U01 NS090501-01]
  2. Biotechnology and Biological Sciences Research Council [BB/K001817/1, BB/R009007/1]
  3. Engineering and Physical Sciences Research Council (EPSRC) [EP/L016737/1, EP/K503733/1]
  4. Wellcome Trust [201964/Z/16/Z]
  5. Royal Academy of Engineering Research Fellowship [RF1415/14/26]
  6. A*STAR Graduate Scholarship
  7. BBSRC [BB/R022437/1, BB/K001817/1, BB/R009007/1] Funding Source: UKRI
  8. EPSRC [EP/J021199/1] Funding Source: UKRI
  9. Wellcome Trust [201964/Z/16/Z] Funding Source: Wellcome Trust

Ask authors/readers for more resources

All optical neurophysiology allows manipulation and readout of neural network activity with single-cell spatial resolution and millisecond temporal resolution. Neurons can be made to express proteins that actuate transmembrane currents upon light absorption, enabling optical control of membrane potential and action potential signalling. In addition, neurons can be genetically or synthetically labelled with fluorescent reporters of changes in intracellular calcitun concentration or membrane potential. Thus, to optically manipulate and readout neural activity in parallel, two spectra are involved: the action spectrum of the actuator, and the absorption spectrum of the fluorescent reporter. Due to overlap in these spectra, previous all-optical neurophysiology paradigms have been hindered by spurious activation of neuronal activity caused by the readout light. Here, we pair the blue-green absorbing optogenetic actuator, Chronos, with a deep red-emitting fluorescent calcium reporter CaSiR-1. We show that cultured Chinese hamster ovary cells transfected with Chronos do not exhibit transmembrane currents when illuminated with wavelengths and intensities suitable for exciting one-photon CaSiR-1 fluorescence. We then demonstrate crosstalk-free, high signalto-noise ratio CaSiR-1 red fluorescence imaging at 100 frames s(-1) of Chronos-mediated calcium transients evoked in neurons with blue light pulses at rates up to 20 Hz. These results indicate that the spectral separation between red light excited fluorophores, excited efficiently at or above 640nm, with blue-green absorbing opsins such as Chronos, is sufficient to avoid spurious opsin actuation by the imaging wavelengths and therefore enable crosstalk-free all-optical neuronal manipulation and readout.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available