4.3 Article

Control rod position measurement by two-electrode capacitance sensor in nuclear heating reactor

Journal

JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
Volume 56, Issue 1, Pages 32-40

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/00223131.2018.1523753

Keywords

Control rod; measurement; two-electrode; experiment; analysis; accuracy

Ask authors/readers for more resources

This study employed a new method for measuring the ungrounded/grounded control rod position. In this connection, a sensor system based on the two-electrode capacitance is applied to measure the rod position in NHR. The application of the capacitance sensor is extensively developed with measuring insulating objects. However, the capacitance sensors measuring for ungrounded/grounded control rod position are seldom studied earlier. In addition, the proposed model was set up with ungrounded/grounded control rod for the two-electrode sensor. According to the different electric properties of ungrounded and grounded control rod, this apparatus determines the control rod position using an interface electronics method and two-electrode capacitance sensor. The subsequent experiment and calibration analyses on the data indicate the high reliability and accuracy of the apparatus for monitoring rod position. It is demonstrated that such a system can be applied to automatic real-time monitoring of control rod positon in nuclear heating reactor.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available