Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner

Journal

ACADEMIC RADIOLOGY
Volume 23, Issue 8, Pages 1008-1014

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.acra.2016.03.015

Keywords

Coronary computed tomography angiography; radiation; low-dose contrast agent volume; ultra-low-dose radiation exposure

Ask authors/readers for more resources

Rationale and Objectives: The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). Materials and Methods: This prospective study was approved by the local ethics committee, and all patients provided written informed consent. Between March and June 2015, 89 consecutive patients (61% male; mean age 55 +/- 11 years) referred for exclusion of CAD by 256-slice CCTA using prospective electrocardiogram triggering were included. Tube voltage (80-120 kVp), tube current (180-310 mA) as well contrast agent volume (25-45 mL) and flow rate (3.5-5 mL/s) were adapted to body mass index. Signal intensity was measured by placing a region of interest in the aortic root, the left main artery, and the proximal right coronary artery. Image noise was measured in the aortic root. Two independent blinded readers semi-quantitatively assessed the image quality regarding motion, noise, and contrast on a 4-point scale. Results: Median contrast agent volume and median effective radiation dose were 35 mL (interquartile range, 30-40 mL) and 0.5 mSv (interquartile range, 0.4-0.6 mSv), respectively. Mean attenuation in the aortic root was 412 89 Hounsfield units. Diagnostic image quality was obtained in 1050 of 1067 (98.4%) coronary segments and, on an intention-to-diagnosis basis, in 85 of 89 (95.5%) patients. Below a cut-off heart rate of 67 beats/min, only 1 of 974 (0.1%) coronary segments was nondiagnostic. Conclusion: A radiation- and contrast-sparing protocol for CCTA on a latest generation 256-slice computed tomography scanner yields diagnostic image quality in patients referred for CAD exclusion in daily clinical routine.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available