Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla

Journal

JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
Volume 47, Issue 3, Pages 461-467

Publisher

CHURCHILL LIVINGSTONE
DOI: 10.1016/j.jcms.2019.01.002

Keywords

Bone mineral density; Cone beam CT; Dental implants; Insertion torque; Maxilla; Resonance frequency analysis

Funding

  1. Dentaurum Implants, Ispringen, Germany
  2. Department of Oral & Maxillofacial Surgery, University of Luebeck, Germany

Ask authors/readers for more resources

Purpose: Primary implant stability is crucial to osseointegration. The aim of this study was to assess correlation of preoperative radiologic parameters with intraoperatively obtained biomechanical tests in the maxilla. Materials and methods: A total of 259 implants were inserted in the maxilla of 99 patients. Cone-beam computed tomography (CBCT)-derived Hounsfield units (HU), voxel grey values and computed tomography mental index (CTMI) performed preoperatively were correlated with insertion torque and Periotest (obtained intraoperatively and 12 weeks later) to assess their prognostic value for primary implant stability. Results: Voxel grey values and insertion torque showed a low correlation (r = 0.329, p = 1.055 x10(-7 )). Likewise, a low correlation was found between HU measured preoperatively and insertion torque as well as intraoperative Periotest values (r = 0.297, p = 4x10(-6) and r = - 0.234, p = 4.35 x 10(-4 ), respectively). A moderate correlation could, however, be assessed between insertion torque and intraoperative as well as Periotest values 12 weeks later. (r = -0.555, p = 1.022 x10(-20) and -0.465. p = 1.150 x 10(-13) ). On contrast, a high correlation was observed between the voxel grey values of CBCT and related HU (r = 0.710, p = 6.486x10(-37) ) so that a conversion from grey values into HU could be suggested. According to regression analysis, an intraoperative negative Periotest value could be expected at an insertion torque of 40 N/cm upwards. Conclusion: CBCT-based bone density parameters correlate with each other and allow conversion of grey scales into HU preoperatively. Both insertion torque and Periotest showed a significant correlation which enables regression analysis to predict implant stability for related insertion torque. On contrast, for HU the distribution curves do not allow a reliable assignment into certain Periotest values. (C) 2019 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available