4.2 Review

Diagnostic Value of Contrast-Enhanced Spectral Mammography in Comparison to Magnetic Resonance Imaging in Breast Lesions

Journal

JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY
Volume 43, Issue 2, Pages 245-251

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RCT.0000000000000832

Keywords

breast cancer; contrast agent; contrast-enhanced spectral mammography; magnetic resonance imaging

Ask authors/readers for more resources

Objective The aim of this study was to evaluate the diagnostic value between contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) in breast disease. Methods Two hundred thirty-five patients who were suspected of having breast abnormalities by clinical examination or mammography underwent CESM and MRI examination. Using histopathologic results as the criterion standard, the diagnostic performance of CESM and MRI was investigated. The areas under receiver operating characteristic curves were applied to analyze diagnostic efficiency. The Pearson correlation coefficients between CESM versus pathology and MRI versus pathology were calculated. Results Two hundred sixty-three breast lesions were found in 235 patients, in which 177 were malignant and 86 were benign. By evaluating the diagnostic value, sensitivity, positive predictive value, negative predictive value, and false-negative rate from CESM examination were comparable to those from MRI (91.5%, 94.7%, 83.7%, and 8.5% vs 91.5%, 90.5%, 82.1%, and 8.5%). Importantly, the accuracy and the specificity were higher for CESM than those for MRI (81% and 89.5% vs 80.2% and 71.7%), whereas the false-positive rate was lower (10.5% vs 19.8%). The areas under receiver operating characteristic curves of CESM and MRI were 0.950 and 0.939, displaying the equivalent diagnostic efficiency (P = 0.48). For the agreement between measurements, mean tumor sizes were 3.1 cm for CESM and 3.4 cm for MRI compared with 3.2 cm on histopathologic results. The Pearson correlation coefficient of CESM versus histopathology (r = 0.774, P = 0.000) was consistent with MRI versus histopathology (r = 0.771, P = 0.000). Conclusions Our results show better accuracy, specificity, and false-positive rate of CESM in breast cancer detection than MRI. Contrast-enhanced spectral mammography displayed a good correlation with histopathology in assessing the lesion size of breast cancer, which is consistent with MRI.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available