Real-time intradermal continuous glucose monitoring using a minimally invasive microneedle-based system

Journal

BIOMEDICAL MICRODEVICES
Volume 20, Issue 4, Pages -

Publisher

SPRINGER
DOI: 10.1007/s10544-018-0349-6

Keywords

Diabetes; Continuous glucose monitoring system (CGMS); Microneedle; Electrochemical biosensor; Biomedical MEMS; Dermal interstitial fluid (ISF)

Funding

  1. Vinnova (Eurostars program) [E!8573]
  2. European Research Council (ERC) [267528]
  3. Foundation Olle Engkvist Byggmastare
  4. Debiotech S.A.

Ask authors/readers for more resources

Continuous glucose monitoring (CGM) has the potential to greatly improve diabetes management. The aim of this work is to show a proof-of-concept CGM device which performs minimally invasive and minimally delayed in-situ glucose sensing in the dermal interstitial fluid, combining the advantages of microneedle-based and commercially available CGM systems. The device is based on the integration of an ultra-miniaturized electrochemical sensing probe in the lumen of a single hollow microneedle, separately realized using standard silicon microfabrication methods. By placing the sensing electrodes inside the lumen facing an opening towards the dermal space, real-time measurement purely can be performed relying on molecular diffusion over a short distance. Furthermore, the device relies only on passive capillary lumen filling without the need for complex fluid extraction mechanisms. Importantly, the transdermal portion of the device is 50 times smaller than that of commercial products. This allows access to the dermis and simultaneously reduces tissue trauma, along with being virtually painless during insertion. The three-electrode enzymatic sensor alone was previously proven to have satisfactory sensitivity (1.5nA/mM), linearity (up to 14mM), selectivity, and long-term stability (up to 4 days) in-vitro. In this work we combine this sensor technology with microneedles for reliable insertion in forearm skin. In-vivo human tests showed the possibility to correctly and dynamically track glycaemia over time, with approximately 10min delay with respect to capillary blood control values, in line with the expected physiological lag time. The proposed device can thus reduce discomfort and potentially enable less invasive real-time CGM in diabetic patients.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available