4.5 Article

Low Noise Nanometer Scale Room-Temperature YBa2Cu3O7-x Bolometers for THz Direct Detection

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TTHZ.2014.2344435

Keywords

Bolometer; responsivity; room temperature operation; THz detectors; YBa2Cu3O7-x (YBCO) film

Funding

  1. Swedish Research Council (VR)

Ask authors/readers for more resources

We present a detailed investigation of the responsivity and the noise in room temperature THz direct detectors made of YBa2Cu3O7-x (YBCO) thin-film nano-bolometers. The YBCO nano-bolometers are integrated with planar spiral antennas covering a frequency range from 100 GHz to 2 THz. The detectors were characterized at 1.6 THz, 0.7 THz, 400 GHz and 100 GHz. The maximum electrical responsivity of 70 V/W and a minimum noise equivalent power (NEP) of 50 pW/Hz(0.5) were measured, whereas the highest optical responsivity was 45 V/W. The (1/f) noise in nano-bolometers is independent on the device volume and can be found as (V-N/V)(2) = 6 x 10(-11) x 1/f Hz(-1) for a given modulation frequency f and a dc voltage V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available