Interscan reproducibility of computer-aided epicardial and thoracic fat measurement from noncontrast cardiac CT

Journal

JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY
Volume 5, Issue 3, Pages 172-179

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcct.2011.03.009

Keywords

Epicardial fat; Noncontrast CT; Reproducibility; Electron beam CT, EBCT; Multidetector CT, MDCT; Thoracic fat

Funding

  1. National Institutes of Health (NIH) from the National Institute of Biomedical Imaging and Bioengineering (NIBIB) [R21EB006829-01A2]
  2. Glazer Foundation [IRB 6318]

Ask authors/readers for more resources

BACKGROUND: Epicardial fat volume (EFV) measured from noncontrast CT is associated with coronary atherosclerosis and increased risk of major adverse cardiovascular events. Interscan reproducibility of EFV quantification from noncontrast CT has not been reported. OBJECTIVE: We evaluated the interscan (intrascanner and interscanner) reproducibility of EFV and thoracic fat volume (TFV) measurements from noncontrast CT. METHODS: We studied 25 consecutive patients who were scanned twice with 4-slice multidetector CT (MDCT), with 120 kVp, 2.5-mm slice thickness (intrascanner) and 23 consecutive patients who were scanned with MDCT and electron beam CT (EBCT) with 3-mm slice thickness (interscanner). For each scan, EFV and TFV were measured from user-defined range of CT slices covering the heart by experienced imaging cardiologists. Voxels within -30 to -190 HU within the epicardial contours was quantified as EFV. TFV was quantified within the heart range automatically. Repeatability coefficient (RC), defined as 1.96 X SD of the differences between pairs of repeated measures, was determined. RESULTS: Correlations for interscan measurements of EFV and TFV were high for both intrascanner (MDCT-MDCT) and interscanner (EBCT-MDCT) data (correlation coefficient >= 0.98). RC values were lowest (4.3% for EFV and 5.4% for TFV) for intrascanner same-observer measurement. For intrascanner cross-observer measurement, RC values were 10.7% for EFV and 9.0% for TFV. For interscanner data, RC values ranged from 6.8% to 8.2%. CONCLUSION: Epicardial and thoracic fat measurements with the use of either MDCT or EBCT are highly reproducible. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available