4.6 Article

A highly sensitive gold nanoparticle bioprobe based electrochemical immunosensor using screen printed graphene biochip

Journal

RSC ADVANCES
Volume 4, Issue 102, Pages 58460-58466

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c4ra11066h

Keywords

-

Ask authors/readers for more resources

This study describes a highly sensitive electrochemical immunosensor for the detection of human chorionic gonadotropin (hCG) that uses gold nanoparticles (AuNP) as the electrochemical label and graphene as electrode material. The primary antibody was first immobilized on the graphene working electrode surface by physical adsorption. Antigen hCG was then added and sandwiched with a secondary antibody labelled with AuNPs. After this, a series of sandwich-type immunoreactions were performed on the electrode, AuNPs were quantified by subjecting the immunocomplex to a preoxidation process of high potential at 1.2 V for 40 s and immediately reduced and scanned by differential pulse voltammtery (DPV). Electrodeposition of gold during the reduction stage of the redox reaction was determined by cyclic voltammetry (CV) that showed a linear relationship with the different hCG concentrations. In this study, a linear relationship between reduction peak current signals and hCG concentration from 0 to 500 pg mL(-1) (correlation coefficient of 0.97351) with a detection limit of 5 pg mL(-1) was obtained.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available