4.5 Article

Experimental Validation of Viscoelastic Coupling Dampers for Enhanced Dynamic Performance of High-Rise Buildings

Journal

JOURNAL OF STRUCTURAL ENGINEERING
Volume 141, Issue 5, Pages -

Publisher

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)ST.1943-541X.0001092

Keywords

High-rise buildings; Wind forces; Vibration; Earthquakes; Full-scale tests; Coupling; Walls; Reinforced concrete; Beams; Viscoelasticity; Experimentation; High-rise buildings; Wind vibrations; Earthquakes; Full-scale tests; Coupled walls; Reinforced concrete coupling beams; Dynamic effects

Funding

  1. Natural Sciences and Engineering Research Council of Canada

Ask authors/readers for more resources

A new damping system, the viscoelastic coupling damper (VCD), has been developed to enhance the wind and seismic performance of coupled shear wall high-rise buildings by adding high damping elements in place of reinforced concrete coupling beams. VCDs replace structural members, such as outriggers or coupling beams, and therefore do not occupy any usable architectural space. When they are properly configured in high-rise buildings, they provide supplemental viscous damping to all lateral modes of vibration, which mitigates building tenant vibration perception problems and reduces both the wind and earthquake response. Experimental results from tests on five small-scale viscoelastic (VE) damper specimens of 5- and 10-mm thicknesses are first presented, followed by the results from six full-scale VCDs representing two alternative configurations. The first was designed for areas where moderate seismic ductility is required, and the second was designed with built-in ductile structural fuses for areas where high seismic ductility is required. The VE material tests exhibited stable hysteretic behavior under the loading conditions that are expected in high-rise buildings under wind and earthquake loading. The full-scale tests validated the overall system performance within a realistic coupled wall configuration, and confirmed the performance of the wall anchorages and all connecting elements as well as the VE material behavior. The full-scale test results also demonstrated the targeted viscoelastic response during wind and low level earthquake loading and the targeted viscoelastic-plastic response for extreme earthquakes, where the response is a combination of the VE response and the nonlinear behavior of the structural fuses.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available