4.5 Article

Concrete-Filled Steel Tube Columns Encased with Thin Precast Concrete

Journal

JOURNAL OF STRUCTURAL ENGINEERING
Volume 141, Issue 12, Pages -

Publisher

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)ST.1943-541X.0001303

Keywords

Composite column; Concrete-filled steel tube; Concrete encasement; Precast concrete; Metal and composite structures

Funding

  1. Shinsegae EC
  2. High-Tech Urban Development Program [09 RD A01]
  3. R&D Policy Infra Program - Ministry of Land, Infrastructure, and Transport (MOLIT) of the Korean Government [11-Technology Standardization-09-01]
  4. National Research Foundation of Korea [2012H1A2A1008342, 22A20130012076] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

An experimental study was performed to investigate the axial-flexural load-carrying capacity of concrete-filled steel tube columns encased with thin precast concrete (PC). Six eccentrically loaded columns and one concentrically loaded column were tested. To prevent the premature failure of the concrete encasement, various reinforcement details such as studs, steel fiber, welded wire mesh, and cross ties were used. The maximum axial loads of the specimens agreed with the strengths predicted by current design codes, although in some specimens, the load-carrying capacity decreased immediately after the peak strength owing to early spalling of the concrete encasement. On the basis of the test results, the use of fiber-reinforced concrete is recommended to increase the ductility of columns by restraining the spalling of the concrete encasement. (C) 2015 American Society of Civil Engineers.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available