4.6 Article

Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT Angiography Results of the PROTECTION II Trial

Journal

JACC-CARDIOVASCULAR IMAGING
Volume 3, Issue 11, Pages 1113-1123

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2010.08.016

Keywords

angiography; computed tomography; imaging; multislice; radiation dose

Ask authors/readers for more resources

OBJECTIVES The purpose of this study was to evaluate image quality and radiation dose using a 100 kVp tube voltage scan protocol compared with standard 120 kVp for coronary computed tomography angiography (CTA) BACKGROUND Concerns have been raised about radiation exposure during coronary CTA The use of a 100 kVp tube voltage scan protocol effectively lowers coronary CTA radiation dose compared with standard 120 kVp, but it is unknown whether image quality is maintained METHODS We enrolled 400 nonobese patients who underwent coronary CTA 202 patients were randomly assigned to a 100 kVp protocol and 198 patients to a 120 kVp protocol The primary end point was to demonstrate noninferiority in image quality with the 100 kVp protocol which was assessed by a 4-point grading score (1 = nondiagnostic, 4 = excellent image quality) For the noninferiority analysis a margin of -02 image quality score points for the difference between both scan protocols was pre-defined Secondary end points included radiation dose and need for additional diagnostic tests during follow up RESULTS The mean image quality scores in patients scanned with 100 kVp and 120 kVp were 3 30 +/- 067 and 3 28 +/- 068, respectively (p = 0742), image quality of the 100 kVp protocol was not inferior as demonstrated by the 97 5% confidence interval of the difference, which did not cross the pre-defined noninferiority margin of -02 The 100 kVp protocol was associated with a 31% relative reduction in radiation exposure (dose-length product 868 +/- 317 mGy x cm with 120 kVp vs 599 +/- 255 mGy x cm with 100 kVp, p < 0 0001) At 30-day follow-up, the need for additional diagnostic studies did not differ (13 4% vs 19 2% for 100 kVp vs 120 kVp, respectively, p = 0 114) CONCLUSIONS A coronary CTA protocol using 100 kVp tube voltage maintained image quality, but reduced radiation exposure by 31% as compared with the standard 120 kVp protocol Thus, 100 kVp scan protocols should be considered for nonobese patients to keep radiation exposure as low as reasonably achievable (Prospective Randomized Trial on Radiation Dose Estimates of Cardiac CT Angiography in Patients Scanned With a 100 kVp Protocol [PROTECTION II], NCT00611780) (J Am Coll Cardiol Img 2010,3 1113-23) (C) 2010 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available