Multi-line NO-LIF thermometry is used to determine the two-dimensional temperature distribution inside a low-pressure plasma reactor. The applicability of multi-line temperature measurements to non-equilibrium plasma environments was evaluated. Temperatures between 300 and 3000 K have been observed, while microwave power, and pressure show a strong effect on the temperature distribution. Metal-organic precursors added for particle synthesis additionally influence the temperature through the heat release during particle formation and the oxidation of organic ligands.