Journal
WATER RESEARCH
Volume 43, Issue 14, Pages 3534-3540Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2009.04.033
Keywords
Micropollutants; Paramagnetic contrast agents; ICP-MS
Funding
- University of Queensland, Veolia Water Australia, and Water Secure
Ask authors/readers for more resources
The use of refractory gadolinium (Gd) complexes as paramagnetic contrast agents in magnetic resonance imaging has resulted in point source release of anthropogenic Gd (Gd(Anth)) into the environment, and presents opportunities to trace the fate of wastewater in natural environments. We demonstrate an inductively coupled plasma mass spectrometry (ICP-MS) technique that is capable of detecting Gd(Anth) at concentrations as low as 48 fM, approximately six orders of magnitude lower than most other micropollutants, without the need for preconcentration. Further, we establish the ubiquitous presence of Gd(Anth) in wastewater at eight separate wastewater treatment plants in Brisbane, Australia, over a 3-month time period. in contrast, there is no evidence of Gd(Anth) in tap water, or in four separate regional water supply dams in South East Queensland, Australia. It is, therefore, highly unlikely that other anthropogenic micropollutants sourced from urban wastewater would be present in the drinking water supply. (C) 2009 Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available