Fetal lung volume and quantification of liver herniation by magnetic resonance imaging in isolated congenital diaphragmatic hernia

Journal

ULTRASOUND IN OBSTETRICS & GYNECOLOGY
Volume 43, Issue 6, Pages 662-669

Publisher

WILEY
DOI: 10.1002/uog.13223

Keywords

congenital diaphragmatic hernia; diaphragm hernia outcomes; fetal lung volumes; fetal ultrasound; liver herniation; lung-to-head ratio; magnetic resonance imaging; prenatal diagnosis; prenatal predictors

Ask authors/readers for more resources

Objective To determine associations between fetal lung and liver herniation volumes measured by magnetic resonance imaging (MRI) and mortality/need for extracorporeal membrane oxygenation (ECMO) in cases of isolated congenital diaphragmatic hernia (CDH). A secondary objective was to compare prenatal MRI parameters with two-dimensional ultrasound lung measurements. Methods A retrospective review of medical records of all fetuses with isolated CDH evaluated between January 2004 and July 2012 was performed. The following MRI parameters were measured at 20-32 weeks: observed/expected total fetal lung volume (o/e-TLV), predicted pulmonary volume (PPV), percentage of liver herniated into the fetal thorax (%LH) and the liver/thoracic volume ratio (LiTR). These were compared with the ultrasound-determined lung-to-head ratio (LHR) and the observed/expected LHR (o/e-LHR) in the same cohort. The predictive value of MRI and ultrasound parameters for mortality and the need for ECMO was evaluated by univariate, multivariate and factor analysis and by receiver-operating characteristics curves. Results Eighty fetuses with isolated CDH were evaluated. Overall mortality was 18/80 (22.5%). Two newborns died a few hours after birth. ECMO was performed in 29/78 (37.2%) newborns, with a survival rate of 48.3% (14/29). The side of the diaphragmatic defect was not associated with mortality (P = 0.99) or the need for ECMO(P = 0.48). Good correlation was observed among o/e-TLV, PPV, LHR and o/e-LHR as well as between %LH and LiTR (r = 0.89; P < 0.01); however, fetal lung measurements and measures of liver herniation were not correlated (all P > 0.05). All parameters were statistically associated with mortality or the need for ECMO. The best combination of measurements to predict mortality was o/e-TLV and %LH, with 83% accuracy. Conclusion Mortality and the need for ECMO in neonates with isolated CDH can be best predicted using a combination of MRI o/e-TLV and %LH. Copyright (C) 2013 ISUOG. Published by John Wiley & Sons Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available