4.3 Article

Feasibility Exploration of Blood Flow Estimation by Contrast-Assisted Nakagami Imaging

Journal

ULTRASONIC IMAGING
Volume 30, Issue 3, Pages 133-150

Publisher

SAGE PUBLICATIONS INC
DOI: 10.1177/016173460803000301

Keywords

Blood flow; contrast agent; microbubble; Nakagami parameter

Funding

  1. Academia Sinica [AS-98-TP-A02]
  2. National Science Council of the Republic of China (Taiwan) [NSC 97-2627-B-007-008]

Ask authors/readers for more resources

The microbubble contrast agent destruction/replenishnient technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this study, we monitored microbubble replenishment by a proposed new approach called the time-Nakagami-parameter curve (TNC) obtained from Nakagami-parameter images for quantifying the flow velocity. The feasibility of using the TNC to estimate the flow was evaluated in computer simulations of the TIC and TNC for flow velocities from 10 to 30 cm/s under an ultrasound frequency of 5 MHz. The clutter effects on the TIC and TNC were explored in a more realistic situation by carrying out phantom measurements of 25 MHz. The rates of increase of the TIC and TNC were expressed by the rate constants beta(1) and beta(N) of a monoexponential model, respectively. The average beta(1) increased from 38 to 110 s(-1) as the flow velocity increased front 10 to 30 cm/s (r = 0.98), and the average beta(N) increased from approximately 40 to 120 s(-1) for the same increase in flow velocity (r = 0.98). The p-value between the results of beta(1) and beta(N) as a function of flow velocity was 0.77. These results represent that beta(N) quantifies the flow velocity similarly to the conventional beta(1). In particular, both the simulation and experimental results revealed that the TNC method conditionally tolerates the presence of nonperfused areas (e.g., surrounding tissues or vessel walls) in the region of interest without requiring application of an additional wall filter to cancel the influences of clutter echoes on the flow estimation. These findings suggest that the TNC-based technique may be a potential method as a complementary tool for the conventional TIC technique to improve the estimation of blood flow.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available