In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44mm (1.30 mm) and 2.54mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85Gy (0.93Gy) and 0.88Gy (0.95Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03Gy (SD=2.27Gy, range: 1.06-8.91Gy).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available