4.2 Article

One-year experience of nucleic acid technology testing for human immunodeficiency virus Type 1, hepatitis C virus, and hepatitis B virus in Thai blood donations

Journal

TRANSFUSION
Volume 49, Issue 6, Pages 1126-1135

Publisher

WILEY
DOI: 10.1111/j.1537-2995.2009.02176.x

Keywords

-

Categories

Funding

  1. National Blood Cente
  2. Thai Red Cross Society
  3. National Institute of Health, Ministry of Public Health
  4. Department of Microbiology, Faculty of Medicine Siriraj Hospital and Department of Pathology, Faculty of Medicine, Ramathibodi Hospital
  5. Chiron Corporation

Ask authors/readers for more resources

Blood donations collected at the National Blood Center, the Thai Red Cross Society, Bangkok, in 2007 were tested by nucleic acid amplification technology (NAT) using the Chiron TIGRIS/Procleix Ultrio test and the Roche cobas s 201/cobas TaqScreen multiplex (MPX) test. The sensitivity, specificity, and robustness were determined by testing 486,676 seronegative blood donations. Samples from each day of collection were divided into two sets; the odd-numbered samples were tested individually on the TIGRIS and the even-numbered samples were tested in pools of 6 on the cobas s 201. The status of reactive samples was confirmed by duplicate testing of samples from the plasma bag to calculate the test specificity. Reactive samples were tested on the alternate system and followed up. The analytical sensitivity of both systems met the 95% limits of detection claimed by the respective package inserts. No cross contamination was seen with either system. Test specificity was 99.93 and 99.90% for the Procleix Ultrio and cobas TaqScreen tests, respectively. The NAT yield rates for human immunodeficiency virus Type 1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) were 1:97,000, 1:490,000, and 1:2800, respectively. Several occult HBV donors, the majority of whom were detected by both tests, were also identified. The HIV-1 and HCV window cases were detected with both tests. The performances of the systems and tests indicated that both were acceptable for routine NAT by the National Blood Center, the Thai Red Cross Society. However, the Procleix Ultrio test appeared to be less sensitive than the cobas TaqScreen test for HBV.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available