4.5 Article

An Impedance-Based Cellular Assay Using Human iPSC-Derived Cardiomyocytes to Quantify Modulators of Cardiac Contractility

Journal

TOXICOLOGICAL SCIENCES
Volume 142, Issue 2, Pages 331-338

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/toxsci/kfu186

Keywords

impedance; human-induced pluripotent stem cells; cardiomyocytes; cardiac contractility; label-free

Categories

Funding

  1. AstraZeneca

Ask authors/readers for more resources

Cardiovascular toxicity, a prominent reason for late-stage failures in drug development, has resulted in a demand for in vitro assays that can predict this liability in early drug discovery. Current in vitro cardiovascular safety testing primarily focuses on ion channel modulation and low throughput cardiomyocyte (CM) contractility measurements. We evaluated both human induced pluripotent stem cell-derived CMs (hiPSC-CMs) and rat neonatal CMs (rat CMs) on the xCELLigence Cardio system which uses impedance technology to quantify CM beating properties in a 96-well format. Forty-nine compounds were tested in concentration-response mode to determine potency for modulation of CM beating, a surrogate biomarker for contractility. These compounds had previously been tested in vivo and in a low throughput in vitro optical-based contractility assay that measures sarcomere shortening in electrically paced dog CMs. In comparison with in vivo contractility effects, hiPSC-CM impedance had assay sensitivity, specificity, and accuracy values of 90%, 74%, and 82%, respectively. These values compared favorably to values reported for the dog CM optical assay (83%, 84%, and 82%) and were slightly better than impedance using rat CMs (77%, 74%, and 74%). The potency values from the hiPSC-CM and rat CM assays spanned four orders of magnitude and correlated with values from the dog CM optical assay (r(2) = 0.76 and 0.70, respectively). The Cardio system assay has >5x higher throughput than the optical assay. Thus, hiPSC-CM impedance testing can help detect the human cardiotoxic potential of novel therapeutics early in drug discovery, and if a hazard is identified, has sufficient throughput to support the design-make-test-analyze cycle to mitigate this liability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available