4.6 Article

Assessment of laboratory assays to measure rivaroxaban - an oral, direct factor Xa inhibitor

Journal

THROMBOSIS AND HAEMOSTASIS
Volume 103, Issue 4, Pages 815-825

Publisher

SCHATTAUER GMBH-VERLAG MEDIZIN NATURWISSENSCHAFTEN
DOI: 10.1160/TH09-03-0176

Keywords

Clotting assays; factor Xa inhibitor; fondaparinux; pharmacodynamics; rivaroxaban; venous thromboembolism

Funding

  1. Bayer Schering Pharma AG
  2. Johnson & Johnson Pharmaceutical Research & Development L.L.C

Ask authors/readers for more resources

Although there is no need for routine coagulation monitoring with rivaroxaban - an oral, direct factor Xa inhibitor - a haemostasis assay might be valuable to measure its pharmacodynamic effects. This study aimed to find assays, among those commercially available, to measure rivaroxaban pharmacodynamics. Several global conventional clotting tests, as well as clotting or chromogenic assays to measure anti-factor Xa activity, were studied. A thrombin generation test using calibrated automated thrombogram was also done. Tests were performed with the indirect factor Xa inhibitor fondaparinux for comparison. A concentration-dependent prolongation of prothrombin time (PT), dilute PT, and activated partial thromboplastin time was observed with rivaroxaban. The results varied depending on the reagents. This variability cannot be standardised with the international normalised ratio system commonly used for vitamin K antagonists. Using a standard calibration curve, PT test results can be expressed in plasma concentrations of rivaroxaban rather than PT seconds or ratio. Standard methods for HepTest and two-step prothrombinase-induced clotting time (PiCT) resulted in a paradoxical response, with low concentrations of rivaroxaban reducing clotting times. This was not observed with shorter incubation times, or when antithrombin-deficient (immunodepleted) plasma was used. The chromogenic tests found a dose-dependent relationship between anti-factor Xa activity and rivaroxaban concentration. Modified specific factor Xa chromogenic assays are being further investigated. One-step PiCT and HepTest with shortened incubation times, as well as the widely available PT assay (using a rivaroxaban calibrator) could be useful to monitor the pharmacodynamic effects of rivaroxaban accurately. Finally, all clotting and chromogenic assays showed a concentration-dependent effect induced by rivaroxaban.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available