4.6 Article

Clinical laboratory measurement of direct factor Xa inhibitors: Anti-Xa assay is preferable to prothrombin time assay

Journal

THROMBOSIS AND HAEMOSTASIS
Volume 104, Issue 6, Pages 1263-1271

Publisher

GEORG THIEME VERLAG KG
DOI: 10.1160/TH10-05-0328

Keywords

Apixaban; factor Xa inhibitor; prothrombin time; international normalised ratio; anti-Xa activity

Funding

  1. Bristol-Myers Squibb
  2. Pfizer Inc.

Ask authors/readers for more resources

Apixaban and other factor Xa (FXa) inhibitors are in late-stage clinical development for prevention and treatment of thromboembolic diseases. Although routine monitoring will not be required, in certain situations assessment of drug level may be helpful.This study evaluated the suitability of commercially available prothrombin time/international normalised ratio (PT/INR) and anti-FXa activity assays to measure FXa inhibitors in plasma. Twelve PT (ISI 0.89-1.88) and three anti-Xa assays were evaluated in vitro using human plasma spiked with four FXa inhibitors (0-2,000 ng/ml). Assay variability and correlation with drug plasma exposure were evaluated in patients with venous thromboembolism (VTE) treated with apixaban. All FXa inhibitors prolonged PT; however, assay sensitivity was dependent on thromboplastin reagents used and FXa inhibitors tested. To achieve a doubling of PT, the concentration of each FXa inhibitor varied 2.6- to 8-fold between thromboplastin reagents. The rank order of a FXa inhibitor's effect on PT ratio varied across thromboplastin reagents. Conversion to INR increased variability. Different anti-Xa assays showed different dynamic ranges for each FXa inhibitor; however, their rank order was consistent. For apixaban, the dynamic range of <7.8-240 ng/ml, and inter- and intraassay precision of <6% coefficient of variation by Rotachrom assay appeared suitable for the anticipated apixaban plasma concentrations with 2.5 and 5 mg bid clinical doses. The stronger correlation between apixaban plasma concentration and anti-Xa activity (r(2) = 0.88-0.89) compared with PT/INR (r(2) = 0.36) in patients undergoing VIE treatment suggested that anti-Xa activity was the better indicator of apixaban plasma concentrations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available