Fast scanning power compensated differential scanning nano-calorimeter: 1. The device

Journal

THERMOCHIMICA ACTA
Volume 505, Issue 1-2, Pages 1-13

Publisher

ELSEVIER
DOI: 10.1016/j.tca.2010.03.019

Keywords

Fast scanning nano-calorimetry; Differential power compensation; Temperature calibration; Crystallization; Metals

Funding

  1. European Union
  2. Humboldt Foundation
  3. Bosch-Foundation
  4. Functional Materials Rostock e.V.

Ask authors/readers for more resources

Fast scanning calorimetry becomes more and more important because an increasing number of materials are created or used far from thermodynamic equilibrium. Fast scanning, especially on cooling, allows for the in situ investigation of structure formation, which is of particular interest in a wide range of materials like polymers, metals, and pharmaceuticals to name a few. Freestanding silicon nitride membranes are commonly used as low addenda heat capacity fast scanning calorimetric sensors. A differential setup based on commercially available sensors is described. To enhance performance of the device a new asymmetric power compensation scheme was developed. The hardware realization of the scheme and calculation of differential power are presented in the first part of this paper. The fast analog amplifiers allow calorimetric measurements up to 100,000 K/s. The lower limit is defined by the sensitivity of the device and is 1 K/s for sharp melting or crystallization events in metals and ca. 100 K/s for broad transitions in polymers. Another limiting factor is accuracy of sample temperature measurement. A strong dependency of temperature on sample placement on the sensor is observed; even reproducibility is within 1 K. For finite sample thicknesses the commonly observed thermal lag must be considered too. Uncertainty of the temperature measurement based on previous thermopile calibration is in the order of +/- 10K. A significant improvement is possible by adding a small particle of a temperature calibration standard, e.g. indium or tin, on top of the sample under investigation. Then uncertainty is about 3 K. The second part of the paper describes sample heat capacity determination and an example to demonstrate the performance of the device. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available