4.4 Article

Development and Evaluation of a Nanoparticle-Based Immunoassay for Determining Paclitaxel Concentrations on Routine Clinical Analyzers

Journal

THERAPEUTIC DRUG MONITORING
Volume 35, Issue 6, Pages 809-815

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/FTD.0b013e318296be01

Keywords

paclitaxel; immunoassay; automated; therapeutic dose management

Funding

  1. Saladax Biomedical Inc.

Ask authors/readers for more resources

Background:Paclitaxel (PTX; Taxol, Abraxane) is used in many regimens for breast cancer, non-small cell lung cancer (NSCLC), and ovarian cancer. Multiple studies have demonstrated that PTX exhibits a greater than 10-fold interpatient variability of clearance rates when patients are dosed according to body surface area (BSA). Pharmacokinetic and pharmacodynamic relationships have been elucidated from BSA-based dosing. PTX is a candidate for dose management, and studies have shown that therapeutic dose management (TDM) is feasible and may provide improved outcomes for patients undergoing treatment.Methods:A PTX immunoassay (MyPaclitaxel) has been developed, which employs a novel PTX monoclonal antibody in a nanoparticle-based turbidimetric assay in a competitive format. Precision, accuracy, and linearity were evaluated by Clinical Laboratory Standards Institute protocols at 3 laboratories on the Olympus AU400 analyzer. Method comparison was done versus a validated high-performance liquid chromatography-tandem mass spectroscopy method using samples (n = 119) collected from patients on PTX therapy.Results:The assay requires 8 L of plasma sample and can produce 400 determinations per hour. The response curve is based on a 6-point nonlinear curve fit and has a range of 0-320 ng/mL, extended to 3200 ng/mL with 10-fold autodilution. Three controls and 4 patient pools were used in precision studies. For all samples across 3 sites, repeatability coefficient of variation percentages ranged 0.9%-4.9%, and within-laboratory coefficient of variation percentages were 1.0%-4.2% with standard curve stability up to 24 days. Linearity was demonstrated over the linear range. Lower limits of detection and quantitation were 11 and 19 ng/mL, respectively. Method comparison results were analyzed by Deming regression, demonstrating a slope = 1.002 and intercept = -3.029 and an R = 0.996. The PTX samples ranged from 24 to 3164 ng/mL with a mean of 745 ng/mL.Conclusions:The analytical performance of an automated immunoassay for PTX has been validated and may serve as a useful tool for TDM of this drug.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available