Journal
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH
Volume 12, Issue 2, Pages 2090-2104Publisher
MDPI
DOI: 10.3390/ijerph120202090
Keywords
-
Funding
- Korea University
Ask authors/readers for more resources
Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul (Korea) and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42%-60% (by weight) of fine particulate matter larger than 1 mu m (PM2.5-1.0) in outdoor samples and 18% of PM2.5-1.0 in subway samples. Iron-containing particles accounted for only 3%-6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM10-2.5) with soil/road dust particles dominating outdoor samples (66%-83%) and iron-containing particles contributing most to subway PM10-2.5 (44%). As expected, soil/road dust particles comprised a greater mass fraction of PM10-2.5 than PM2.5-1.0. Also as expected, the mass fraction of iron-containing particles was substantially less in PM10-2.5 than in PM2.5-1.0. Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM2.5-1.0 and PM10-2.5 simultaneously and by composition at multiple locations.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available