4.7 Article

Amplified cathodic electrochemiluminescence of luminol based on Pd and Pt nanoparticles and glucose oxidase decorated graphene as trace label for ultrasensitive detection of protein

Journal

TALANTA
Volume 113, Issue -, Pages 106-112

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2013.03.018

Keywords

Electrochemiluminescence; Luminol; Graphene; Glucose oxidase; Nanoparticles; Hydrogen peroxide

Funding

  1. NNSF of China [21075100]
  2. State Key Laboratory of Electroanalytical Chemistry [SKLEAC2010009]
  3. Ministry of Education of China [708073]
  4. Natural Science Foundation of Chongqing City [CSTC-2009BA1003, CSTC-2010BB4121, CSTC-2011BA7003]
  5. Specialized Research Fund for the Doctoral Program of Higher Education [20100182110015]
  6. Postgraduate Science and Technology Innovation Program of Southwest China University [KB2010006]

Ask authors/readers for more resources

An ultrasensitive electrochemiluminescence (ECL) irnmunosensor was constructed for ultrasensitive detection of carcinoembryonic antigen (CEA) based on an amplified cathodic ECL of luminol at low potential. Firstly, Au nanoparticles (AuNPs) were electrodeposited onto single walled carbon nanotube-graphene composites (CNTs-Gra) coated glass carbon electrode (GCE) with enhanced surface area and good biocompatibility to capture primary antibody (Ab(1)) and then bind the antigen analytes. Secondly, Pd and Pt nanoparticles (Pd&PtNPs) decorated reduted graphene oxide (Pd&PtNPs@rGO) and glucose oxidase (GOD) labeled secondary antibody (Pd&PtNPs@ rGO-GOD-Ab(2)) could be captured onto the electrode surface by a sandwich immunoassay protocol to generate amplified cathodic ECL signals of luminol in the presence of glucose. The Pd&PtNPs@rGO composites and loaded GOD promoted luminol cathodic ECL response by efficiently catalyzing glucose to in-situ produce amount of hydrogen peroxide (H2O2) working as a coreactant of luminol. Then in turn Pd&PtNPs catalyzed H2O2 to generate various reactive oxygen species (ROSs), which accelerated the cathodic ECL reaction of luminol, enhanced the cathodic ECL intensity of luminol and improved the sensitivity of the immunosensor. The as-proposed ECL immunosensor exhibited sensitive response on the detection of CEA ranging from 0.0001 ng mL(-1) to 160 ng mL(-1) with a detection limit of 0.03 pg mL1 (S/N =3). Moreover, the stability, specificity, lifetime and reproducibility tests demonstrated the feasibility of the developed immunoassay, which can be further extended to the detection of other disease biomarkers. (C) 2013 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available