Very low optical absorptions and analyte concentrations in water measured by Optimized Thermal Lens Spectrometry

Journal

TALANTA
Volume 85, Issue 2, Pages 850-858

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2011.04.015

Keywords

Thermal Lens Spectrometry; Water; Chromium(III); Absorption spectrum; High sensitivity

Funding

  1. FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)
  2. CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior)
  3. CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico)
  4. FAPERJ (Fundacao de Amparo a Pesquisa do Estado do Rio de Janeiro)

Ask authors/readers for more resources

Thermal Lens Spectrometry has traditionally been carried out in the single-beam and the mode-mismatched dual-beam configurations. Recently, a much more sensitive dual-beam TL setup was developed, where the probe beam is expanded and collimated. This feature optimizes Thermal Lens (TL) signal and allows the use of thicker samples, further improving the sensitivity. In this paper, we have made comparisons between the conventional and optimized TL configurations, and presented applications such as measurements of very low absorptions and concentrations in water and Cr(III) aqueous solution in the UV-vis range. For pure water we found linear absorption coefficients as low as the Raman scattering one due to the stretching vibrational modes of OH group. The detection limit was estimated 1 x 10(-6) cm(-1) with a 180-mW excitation power using a 100-mm cell length. This sensitivity is very high, considering that water has a photothermal enhancement factor similar to 33 times smaller than CCl4, for example. For Cr(III) species in aqueous solution, the limit of detection (LOD) was estimated in similar to 40 ng mL(-1) at 514 nm, or similar to 10ng mL(-1) at 405 nm, which is similar to 30 times smaller than the LOD achieved with conventional transmission techniques. The more recent TL configuration is very attractive to obtain absorption spectra, since the result does not depend critically on the beam parameters, unlike the other configurations. The main drawbacks of this optimized TL configuration are the longer acquisition time and the need for larger samples. (C) 2011 Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available