4.7 Article

An LC-MS method for the determination of pharmaceutical compounds in wastewater treatment plant influent and effluent samples

Journal

TALANTA
Volume 75, Issue 4, Pages 1089-1097

Publisher

ELSEVIER
DOI: 10.1016/j.talanta.2008.01.011

Keywords

LC-MS/MS; pharmaceuticals; wastewater treatment plant

Ask authors/readers for more resources

Pharmaceuticals are continually introduced into the environment as a result of industrial and domestic use. In recent years they have emerged as environmental pollutants. An analytical method has been developed allowing for simultaneous detection and identification of 20 pharmaceutical compounds from various therapeutic classes using solid phase extraction (SPE) followed by liquid chromatography-electrospray ionisation mass spectrometry (LC-MS/MS). The limits of detection and limits of quantitation for the method were in the ng/L-mu g/L range. The method was applied to influent and effluent samples from three wastewater treatment plants (WWTPs). Fifteen compounds were identified in the sample matrix with salicylic acid and ibuprofen being the most abundant at 9.17 and 3.20 mu g/L respectively. (c) 2008 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available