4.7 Article

Detection of Atrial Fibrillation After Ischemic Stroke or Transient Ischemic Attack A Systematic Review and Meta-Analysis

Journal

STROKE
Volume 45, Issue 2, Pages 520-526

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/STROKEAHA.113.003433

Keywords

atrial fibrillation; ischemic attack; transient; stroke

Funding

  1. North Western Deanery
  2. Salford Royal NHS Foundation Trust
  3. University of Manchester
  4. University of Glasgow

Ask authors/readers for more resources

Background and Purpose Atrial fibrillation (AF) confers a high risk of recurrent stroke, although detection methods and definitions of paroxysmal AF during screening vary. We therefore undertook a systematic review and meta-analysis to determine the frequency of newly detected AF using noninvasive or invasive cardiac monitoring after ischemic stroke or transient ischemic attack. Methods Prospective observational studies or randomized controlled trials of patients with ischemic stroke, transient ischemic attack, or both, who underwent any cardiac monitoring for a minimum of 12 hours, were included after electronic searches of multiple databases. The primary outcome was detection of any new AF during the monitoring period. We prespecified subgroup analysis of selected (prescreened or cryptogenic) versus unselected patients and according to duration of monitoring. Results A total of 32 studies were analyzed. The overall detection rate of any AF was 11.5% (95% confidence interval, 8.9%-14.3%), although the timing, duration, method of monitoring, and reporting of diagnostic criteria used for paroxysmal AF varied. Detection rates were higher in selected (13.4%; 95% confidence interval, 9.0%-18.4%) than in unselected patients (6.2%; 95% confidence interval, 4.4%-8.3%). There was substantial heterogeneity even within specified subgroups. Conclusions Detection of AF was highly variable, and the review was limited by small sample sizes and marked heterogeneity. Further studies are required to inform patient selection, optimal timing, methods, and duration of monitoring for detection of AF/paroxysmal AF.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available