4.7 Article

Quantitative Analysis of Hypoperfusion in Acute Stroke Arterial Spin Labeling Versus Dynamic Susceptibility Contrast

Journal

STROKE
Volume 44, Issue 11, Pages 3090-3096

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/STROKEAHA.113.002377

Keywords

ASL; cerebral revascularization; perfusion-weighted MRI; reperfusion; stroke

Funding

  1. NINDS NIH HHS [K24 NS072272] Funding Source: Medline

Ask authors/readers for more resources

Background and Purpose This study compares the concordance between arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) for the identification of regional hypoperfusion and diffusion-perfusion mismatch tissue classification using a quantitative method. Methods The inclusion criteria for this retrospective study were as follows: patients with acute ischemic syndrome with symptom onset <24 hours and acquisition of both ASL and DSC MR perfusion. The volumes of infarction and hypoperfused lesions were calculated on ASL and DSC multi-parametric maps. Patients were classified into reperfused, matched, or mismatch groups using time to maximum >6 sec as the reference. In a subset of patients who were successfully recanalized, the identical analysis was performed and the infarction and hypoperfused lesion volumes were used for paired pre- and posttreatment comparisons. Results Forty-one patients met our inclusion criteria. Twenty patients underwent successful endovascular revascularization (TICI>2a), resulting in a total of 61 ASL-DSC data pairs for comparison. The hypoperfusion volume on ASL-cerebral blood flow best approximated the DSC-time to peak volume (r=0.83) in pretreatment group and time to maximum (r=0.46) after recanalization. Both ASL-cerebral blood flow and DSC-TTP overestimated the hypoperfusion volume compared with time to maximum volume in pretreatment (F=27.41, P<0.0001) and recanalized patients (F=8.78, P<0.0001). Conclusions ASL-cerebral blood flow overestimates the DSC time to maximum hypoperfusion volume and mismatch classification in patients with acute ischemic syndrome. Continued overestimation of hypoperfused volume after recanalization suggests flow pattern and velocity changes in addition to arterial transit delay can affects the performance of ASL.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available