4.1 Article

Pathways of Infusate Loss during Convection-Enhanced Delivery into the Putamen Nucleus

Journal

STEREOTACTIC AND FUNCTIONAL NEUROSURGERY
Volume 91, Issue 2, Pages 69-78

Publisher

KARGER
DOI: 10.1159/000342492

Keywords

Parkinson's disease; Convection-enhanced delivery; Intraputaminal infusion; Magnetic resonance imaging

Funding

  1. Kinetics Foundation
  2. NIH-NCRR [P51 RR000167]
  3. Research Facilities Improvement Program [RR15459-01, RR020141-01]

Ask authors/readers for more resources

Background: New strategies aiming to treat Parkinson's disease, such as delivery of trophic factors via protein infusion or gene transfer, depend upon localized intracerebral infusion, mainly into the putamen nucleus. Convection-enhanced delivery (CED) has been proposed as a method to improve intracerebral distribution of therapies. Yet analysis of controversial results during the clinical translation of these strategies suggests that intracerebral misdistribution of infusate may have affected the outcomes by limiting the amount of treatment into the target region. Objectives: This study aimed to identify possible pathways of infusate loss and their relative impact in the success of targeted CED into the postcommissural ventral putamen nucleus. Methods: Thirteen adult macaque monkeys received intraputaminal CED infusions of 100 mu l of 2.0 mM gadoteridol and bromophenol blue (0.16 mg/ml) solution at a rate of 1.0 mu l/min under intraoperative magnetic resonance imaging (MRI) guidance. Quantitative maps of infusate concentration were computed at 10-min intervals throughout the procedure in a 3-Tesla MRI scanner. The fraction of tracer lost from the putamen as well as the path of loss were evaluated and quantified for each infusion. Results: All injections (total 22) were successfully placed in the ventral postcommissural putamen nucleus. Four major paths of infusate loss from the putamen were observed: overflow across putamen boundaries, perivascular flow along large blood vessels, backflow along the inserted catheter and catheter tract leakage into the vacated catheter tract upon catheter removal. Overflow loss was observed within the first 30 mu l of infusion in all cases. Measurable tracer loss following the path of an artery out of the putamen was observed in 15 cases, and in 8 of these cases, the loss was greater than 10% of infusate. Backflow that exited the putamen was observed in 4 cases and led to large loss of infusate (80% in 1 case) into the corona radiata. Loss into the vacated catheter tract amounted only to a few microliters. Conclusions: Our analysis demonstrates that after controlling for targeting, catheter type, infusion rate and infusate, the main issues during surgical planning are the identification of appropriate infusate volume that matches the target area, as well as mapping the regional vasculature as it may become a pathway for infusate loss. Most importantly, these results underscore the significance of presurgical planning for catheter placement and infusion, and the value of imaging guidance to ensure targeting accuracy. Copyright (c) 2013 S. Karger AG, Basel

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available