4.6 Article

A novel alternative for removal of the AxiaLif (TranS1) in the setting of pseudarthrosis of L5-S1

Journal

SPINE JOURNAL
Volume 9, Issue 11, Pages 910-915

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.spinee.2009.08.459

Keywords

Minimally invasive spine surgery; AxiaLif TranS1; Pseudarthrosis; Revision spine surgery; Anterior lumbar interbody fusion

Ask authors/readers for more resources

BACKGROUND: Minimally invasive spine surgery continues to be a growing trend for orthopedic and neurosurgical spinal interventions. Technological advances have allowed surgeons to perform L5-S1 fusions via posterolateral or anterior approaches through less invasive techniques. The development of the AxiaLIF system (TranS1, Inc., Wilmington, NC) is predicated on the application of minimally invasive techniques to attain fusion at L5-S1 and L4-S1 levels with a novel corridor of approach, described as the presacral safe zone. PURPOSE: The authors describe an alternative approach for removing a L5-S1 transsacral implant that was placed through a percutaneous paracoccygeal approach using the presacral safe zone. The purpose of this technical note is to demonstrate that use of the previous percutaneous presacral tract, as recommended by the manufacturer, is not mandatory. In cases of anterior pseudarthrosis following this device, a paramedian retroperitoneal approach to L5-S1 not only allows for adequate visualization for revision but also provides adequate and safe caudal exposure over the sacral promontory to remove the implant through its previous osseous path. STUDY DESIGN/SETTING: This technical note highlights the concerns for revision of the AxiaLif (TranS1) screw through the presacral scarred tract. METHODS: The AxiaLif (TranS1), used in this case is an alternative method to anterior, posterior, or transforaminal lumbar interbody fusion. Removal of this implant for pseudarthrosis was performed through a paramedian retroperitoneal approach with caudal extension. After anterior discectomy, the AxiaLif screw was removed via manipulation through the disc space and delivered through the sacrum. This was followed by complete discectomy and bone grafting of the voids left in the L5 and sacral vertebral bodies. Standard anterior lumbar interbody reconstruction was then performed using a polyetheretherketone implant followed by revision of the pedicle screw construct posteriorly. RESULTS: Preoperative symptoms were resolved in the immediate postoperative period secondary to the immediate stability afforded by the revision of the loose implants. Fusion was achieved within 6 months and confirmed with fine-cut computed tomography images. CONCLUSION: This novel technique of avoiding a scarred down presacral corridor in the hands of surgeons unfamiliar with the technique allows for safe removal of the AxiaLif (TranS1) implant coupled with revision to anterior lumbar interbody fusion through the same incision. (C) 2009 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available