4.5 Article

In Vivo Analysis of Insertional Torque During Pedicle Screwing Using Cortical Bone Trajectory Technique

Journal

SPINE
Volume 39, Issue 4, Pages E240-E245

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0000000000000116

Keywords

cortical bone trajectory; insertional torque; pedicle screw; bone mineral density; screw stability

Ask authors/readers for more resources

Study Design. The insertional torque of pedicle screws using the cortical bone trajectory (CBT) was measured in vivo. Objective. To investigate the effectiveness of the CBT technique bymeasurement of the insertional torque. Summary of Background Data. The CBT follows a mediolateral and caudocephalad directed path, engaging with cortical bone maximally from the pedicle to the vertebral body. Some biomechanical studies have demonstrated favorable characteristics of the CBT technique in cadaveric lumbar spine. However, no in vivo study has been reported on the mechanical behavior of this new trajectory. Methods. The insertional torque of pedicle screws using CBT and traditional techniques were measured intraoperatively in 48 consecutive patients. A total of 162 screws using the CBT technique and 36 screws using the traditional technique were compared. In 8 of 48 patients, the side-by-side comparison of 2 different insertional techniques for each vertebra were performed, which formed the H group. In addition, the insertional torque was correlated with bone mineral density. Results. The mean maximum insertional torque of CBT screws and traditional screws were 2.49 +/- 0.99 Nm and 1.24 +/- 0.54 Nm, respectively. The CBT screws showed 2.01 times higher torque and the difference was significant between the 2 techniques (P < 0.01). In the H group, the insertional torque were 2.71 +/- 1.36 Nm in the CBT screws and 1.58 +/- 0.44 Nm in the traditional screws. The CBT screws demonstrated 1.71 times higher torque and statistical significance was achieved (P < 0.01). Positive linear correlations between maximum insertional torque and bone mineral density were found in both technique, the correlation coefficient of traditional screws (r = 0.63, P < 0.01) was higher than that of the CBT screws (r = 0.59, P < 0.01). Conclusion. The insertional torque using the CBT technique is about 1.7 times higher than the traditional technique.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available