4.5 Article

Biomechanical Stability of Lateral Interbody Implants and Supplemental Fixation in a Cadaveric Degenerative Spondylolisthesis Model

Journal

SPINE
Volume 39, Issue 19, Pages E1138-E1146

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0000000000000485

Keywords

degenerative spondylolisthesis; XLIF; extreme lateral; stability; range of motion (ROM); lumbar interbody fusion; shear loading; shear displacement

Funding

  1. NuVasive Inc.

Ask authors/readers for more resources

Study Design. In vitro cadaveric biomechanical study of lateral interbody cages and supplemental fixation in a degenerative spondylolisthesis (DS) model. Objective. To investigate changes in shear and flexion-extension stability of lateral interbody fusion constructs. Summary of Background Data. Instability associated with DS may increase postoperative treatment complications. Several groups have investigated DS in cadaveric spines. Extreme lateral interbody fusion (XLIF) cages with supplemental fixation have not previously been examined using a DS model. Methods. Seven human cadaveric L4-L5 motion segments were evaluated using flexion-extension moments to +/- 7.5 N.m and anterior-posterior (A-P) shear loading of 150 N with a static axial compressive load of 300 N. Conditions were: (1) intact segment, (2) DS simulation with facet resection and lateral discectomy, (3) standalone XLIF cage, (4) XLIF cage with (1) lateral plate, (2) lateral plate and unilateral pedicle screws contralateral to the plate (PS), (3) unilateral PS, (4) bilateral PS, (5) spinous process plate, and (6) lateral plate and spinous process plate. Flexion-extension range of motion (ROM) data were compared between conditions and with results from a previous study without DS simulation. A-P shear displacements were compared between conditions. Results. Flexion-extension ROM after DS destabilization increased significantly by 181% of intact ROM. With the XLIF cage alone, ROM decreased to 77% of intact. All conditions were less stable than corresponding conditions with intact posterior elements except those including the spinous process plate. Under shear loading, A-P displacement with the XLIF cage alone increased by 2.2 times intact. Bilateral PS provided the largest reduction of A-P displacement, whereas the spinous process plate alone provided the least. Conclusion. This is the first in vitro shear load testing of XLIF cages with supplemental fixation in a cadaveric DS model. The variability in sagittal plane construct stability, including significantly increased flexion-extension ROM found with most fixation conditions including bilateral PS may explain some clinical treatment complications in DS with residual instability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available