4.6 Article

Deterinination of As, Cd, Pb, and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer

Journal

SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
Volume 63, Issue 3, Pages 389-395

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.sab.2007.11.033

Keywords

inductively coupled plasma mass spectrometry; direct injection high efficiency nebulizer; urine; mercury

Categories

Ask authors/readers for more resources

The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., (40)AT(35)Cl(+) on As-75(+) and (MoO+)-Mo-98-O-16 on Cd-114(+)) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, especially for analytes such as Hg. The Dynamic Reaction Cell (DRC) is used in this study to attenuate the background level of ArCl+ in spite of the increase in the solvent load and, in turn, the urine matrix (chloride) delivered to the plasma by the LB-DIHEN. This is the first report on coupling the LB-DIHEN to a standard autosampler for unattended sample, analysis. The robustness of direct injection nebulization for routine analysis and the issues associated with automation of the sample introduction process are discussed. Although the figures of merit (sensitivity, limit of detection, and precision) determined for both nebulizers are slightly poorer for the LB-DIHEN than for the concentric pneumatic nebulizer, there is not a clinically significant difference between the results for both sample introduction systems. The accuracy of results is assessed using archived urine materials that are circulated by several different proficiency testing (PT) programs and external quality assessment schemes (EQAS). Results obtained using the LB-DIHEN were within the acceptable range established by a consensus pool generated using different methods, none of which are likely to be using direct injection nebulization. Internal quality control sample results obtained using the LB-DIHEN were compared to those obtained using the conventional nebulizer. Reported results were similar for both nebulizers. Thus, these results show that the LB-DIHEN is certainly feasible for the analysis of urine specimens. (c) 2007 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available