4.6 Article Proceedings Paper

Shear Stability of EOR Polymers

Journal

SPE JOURNAL
Volume 17, Issue 2, Pages 335-339

Publisher

SOC PETROLEUM ENG
DOI: 10.2118/141113-PA

Keywords

-

Ask authors/readers for more resources

An experimental study of shear stability of several high-molecular-weight polymers used as mobility-control agents in EOR projects has been performed in well-controlled conditions. The shearing device was made of a capillary tube with an internal diameter (ID) of 125 mu m, through which polymer solution was injected at a controlled rate. The setup enables a precise measurement of the shear rate to which the polymer macromolecule is submitted. The degradation rate was measured by the viscosity loss induced by the passage into the capillary tube. The shear rate was gradually increased up to 10(6) sec(-1) while checking degradation rate at each stage. Different commercial EOR polymer products were submitted to the test with polyacrylamide backbone and different substitution monomer groups. All macromolecules behave as flexible coils in solution. The parameters investigated were Molecular weight (between 6 and 20x10(6)) Nature of substitution group (acrylate, ATBS/sulfonate, nVP/vinyl-pyrrolidone) Salinity Polymer shear degradation increases with molecular weight and salinity, but decreases with the presence of acrylate, ATBS, and nVP. All results can be interpreted in terms of chain flexibility. The highly flexible polyacrylamide homopolymer is the most sensitive to shear degradation. Introduction of acrylate groups in the polymer chain induces some stability because of the rigidity provided by charge repulsion, which vanishes in the presence of high salinity because of the screening of acrylate negative charges. ATBS and VP groups, which are larger in size, provide significant chain rigidity, and thus better shear stability. It is also shown that some very-high-molecular-weight polymers, after passing the shearing device, attain a final viscosity lower than lower-molecular-weight products with the same chemical composition. This factor has to be taken into account in the final choice of a polymer for a given field application. As a comparison, although less popular today than 2 decades ago, xanthan gum (XG), which behaves like a semirigid rod, is shown to be much less sensitive to the shear-degradation test than the coiled polyacrylamides (Sorbie 1991).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available