4.6 Article

Capacitive Coulter counting: detection of metal wear particles in lubricant using a microfluidic device

Journal

SMART MATERIALS AND STRUCTURES
Volume 18, Issue 3, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.1088/0964-1726/18/3/037001

Keywords

-

Funding

  1. National Science Foundation [ECCS-0748540, DBI-0649798]

Ask authors/readers for more resources

A microfluidic device based on the capacitance Coulter counting principle to detect metal debris particles in lubricant oil is presented. The device scans each individual metal debris particle as they pass through a microfluidic channel by monitoring the capacitance change. We first proved the feasibility of using the capacitance Coulter counting principle for detecting metal particles in a fluidic channel. Next, we tested the microfluidic device with aluminum abrasive particles ranging from 10 to 25 mu m; the testing results show the microfluidic device is capable of detecting metal wear particles in low-conductive lubricant oil. The design concept demonstrated here can be extended to a device with multiple microchannels for rapid detection of metal wear particles in a large volume of lubricant oil.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available