4.3 Article Proceedings Paper

Auto bi-level with pressure relief during exhalation as a rescue therapy for optimally treated obstructive sleep apnoea patients with poor compliance to continuous positive airways pressure therapy-a pilot study

Journal

SLEEP AND BREATHING
Volume 15, Issue 1, Pages 21-27

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s11325-009-0322-y

Keywords

Obstructive sleep apnoea; Continuous positive airways pressure; Bi-level; Auto bi-level; BiPAP; Pressure relief; Compliance

Ask authors/readers for more resources

Continuous positive airways pressure (CPAP) is the accepted therapy for obstructive sleep apnoea (OSA), but compliance is variable. We hypothesised that an auto bi-level device with pressure relief during exhalation (auto bi-level) would treat OSA as well as CPAP and that transitioning non-compliant CPAP patients without modifiable causes of poor compliance to this device would improve compliance and clinical outcomes. OSA patient's on positive airways pressure therapy with compliance below 4 h of use on a parts per thousand yen70% of nights over the past 3 months despite having no modifiable causes of poor compliance were transitioned onto an auto bi-level device for 10 weeks. Patients completed an Epworth sleepiness scale and Functional Outcomes of Sleep Questionnaire (FOSQ) at 15 days and 10 weeks and had their compliance and therapy data downloaded. Additionally, patients underwent polysomnography on their auto bi-level device at week 10. Thirty-five patients were included. The apnoea-hypopnoea index, arousal index, sleep efficiency, total sleep time and sleep stage distribution were similar at baseline and week 10. Compliance, excessive daytime sleepiness and several FOSQ domains improved significantly at day 15 and week 10. Patients requiring an effective pressure a parts per thousand yen10 cmH(2)0 during the lead-in period on CPAP experienced greater significant improvements compliance than those requiring an effective pressure < 10 cmH(2)0. Auto bi-level with pressure relief during exhalation treats OSA as effectively as CPAP without inducing additional arousals. Transitioning non-compliant CPAP patients without modifiable causes of poor compliance from their CPAP to this new device improves compliance and clinical outcomes over a 10-week period.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available