4.7 Article

Influence of humidity on CO sensing with p-type CuO thick film gas sensors

Journal

SENSORS AND ACTUATORS B-CHEMICAL
Volume 153, Issue 2, Pages 347-353

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2010.10.046

Keywords

p-Type MOX; CuO; CO; Modeling; Water cross-interference

Funding

  1. Romanian National Authority for Scientific Research through the CNCSIS [PCCE-ID-76]
  2. Core Program contract [PN09-45]

Ask authors/readers for more resources

A model for the detection of CO in the presence of humidity is proposed for thick porous film gas sensors based on p-type CuO. The sensing mechanism is investigated by means of simultaneous DC electrical resistance and work function changes measurements combined with appropriate modeling of the conduction in the polycrystalline sensing film. The experiments were performed at 150 degrees C in dry and humid air backgrounds. The conclusion is that, very similarly to the case of undoped SnO2, the explanation of the cross-interference of water in the CO detection is the fact that both react with pre-adsorbed oxygen ions. (C) 2010 Elsevier B.V. All rights reserved.