Journal
SCIENCE AND TECHNOLOGY OF WELDING AND JOINING
Volume 13, Issue 7, Pages 629-637Publisher
MANEY PUBLISHING
DOI: 10.1179/136217108X363900
Keywords
Spot friction welding; Lap shear load; Temperature measurement
Funding
- Ford Motor Company
Ask authors/readers for more resources
The effect of process parameters cycle time, tool speed and axial force) on the specimen temperature measured 2 mm away from the weld in spot friction welding (SFW) of Al 6111-T4 is investigated. The temperatures were correlated to the lap shear load. Results revealed that, to achieve a good joint strength with the maximum lap shear load > 2.5 kN, temperatures should be greater than a threshold value, which is 350 degrees C at a location close to the SFW joint in this study. By studying the specimen macrographs, two internal weld geometric features based on the cross-section area were identified and correlated to the shear and mixed failure modes of the lap shear tested specimens. A model was developed and validated using experimental data of the cross-section area of SFW joint with either shear or mixed mode fracture. The model predicts that the SFW joint strength is maximised at the transition region between the shear and mixed mode fracture.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available