Improved pyroelectric detectors for single crystal adsorption calorimetry from 100 to 350 K

Journal

REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 81, Issue 2, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.3290632

Keywords

adsorption; annealing; calorimetry; coatings; etching; heat of adsorption; heat of formation; monolayers; polymers; pyroelectric detectors

Funding

  1. National Science Foundation [CHE-0757221]

Ask authors/readers for more resources

The adsorption of atoms and molecules on single crystal surfaces allows one to produce well-characterized atomic, molecular, or dissociated adsorbates. Microcalorimetric measurement of the resulting adsorption energies, i.e., single crystal adsorption calorimetry, allows determination of the standard enthalpies of formation of these adsorbates. Methods are described for making an improved heat detector for such measurements, which greatly improves the signal-to-noise ratio, particularly at low temperatures (down to 100 K). The heat detector is an adaptation of a previously introduced design, based on a metallized pyroelectric polymer (beta-polyvinylidene fluoride), which is pressed against the back of a single crystal during measurement but removed during sample preparation and annealing. The improvement is achieved by selectively etching the metal coating of the polymer, thus reducing the pyro- and piezoelectric noise from all nonessential regions of the polymer. We, furthermore, describe how to achieve a better thermal contact between the sample and the pyroelectric polymer, without increasing the thermal mass of the detector, resulting in significantly improved sensitivities for both 1 and 127 mu m thick samples. The result is a detector which, using 1 mu m samples, is similar to 40 times more sensitive at 100 K than the traditional polymer-based detector, showing a pulse-to-pulse standard deviation in the heat of adsorption of just 1.3 kJ/mol with gas pulses containing only 1.1% of a monolayer onto Pt(111), for which 1 ML (monolayer) is 1.5x10(15) species/cm(2). For measurements at 300 K, where especially pyroelectric noise is likely of less concern, the new design improves the sensitivity 3.6-fold compared to the traditional detector. These improvements are furthermore used to propose a new detector design that is able to measure heats of adsorption on samples as thick as 127 mu m with reasonable sensitivity.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available