4.5 Article

Femoro-iliacal artery versus pulmonary artery core temperature measurement during therapeutic hypothermia: An observational study

Journal

RESUSCITATION
Volume 84, Issue 6, Pages 805-809

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.resuscitation.2012.11.022

Keywords

Body temperature; Induced hypothermia; Cardiopulmonary resuscitation; Catheterization; Swan Ganz; Pulse contour cardiac output; Temperature measurement

Funding

  1. Oesterreichische Nationalbank (Anniversary Fund) [AP12934ONB]

Ask authors/readers for more resources

Aim of the study: Therapeutic hypothermia after cardiac arrest improves neurologic outcome. The temperature measured in the pulmonary artery is considered to best reflect core temperature, yet is limited by invasiveness. Recently a femoro-arterial thermodilution catheter (PiCCO-Pulse Contour Cardiac Output) has been introduced in clinical practice as a safe and accurate haemodynamic monitoring system, which is also able to measure blood temperature. The aim of the study was to investigate, if the temperature measured with the PiCCO catheter reflects pulmonary artery temperature better than other sites during therapeutic hypothermia. Methods: In this observational study twenty patients after cardiac arrest and successful resuscitation were cooled with various cooling methods to 33 +/- 1 degrees C for 24 h, followed by rewarming. Temperatures were recorded continuously in the pulmonary artery (Tpa), femoro-iliacal artery (Tpicco), ear canal (Tear), oesophagus (Toeso) and urinary bladder (Tbla). We assessed agreement of methods using the Bland Altman approach including bias and limits of agreement (LA). Results: All other sites differed significantly from Tpa with the bias varying from 0.4 degrees C (Tbla) to -0.6 degrees C (Tear). Standard deviations varied from 0.1 degrees C (Tpicco, Toeso) to 0.5 degrees C (Tear). For all sites bias was closer to zero with increasing average temperatures. Bias tended to be larger in the cooling phase compared to overall measurements. Conclusions: Temperature measurement in the femoro-iliacal artery (Tpicco) reflects the gold standard of pulmonary artery temperature most accurately, especially during the cooling phase. Tpicco is easily accessible and might be used for monitoring core temperature without the need for additional temperature probes. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available