4.5 Article

Electrical Stimulation Versus Ultrasound Guidance for Popliteal-Sciatic Perineural Catheter Insertion A Randomized Controlled Trial

Journal

REGIONAL ANESTHESIA AND PAIN MEDICINE
Volume 34, Issue 5, Pages 480-485

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1097/AAP.0b013e3181ada57a

Keywords

-

Categories

Funding

  1. National Institutes of Health [GM077026]
  2. National Institute of General Medical Sciences
  3. Department of Anesthesiology, University of California, San Diego Medical Center (San Diego, Calif)

Ask authors/readers for more resources

Background: Sciatic perineural catheters via a popliteal fossa approach and subsequent local anesthetic infusion provide potent analgesia and other benefits after foot and ankle surgery. Electrical stimulation (ES) and, more recently, ultrasound (US)-guided placement techniques have been described. However, because these techniques have not been compared in a randomized fashion, the optimal method remains undetermined. Therefore, we tested the hypotheses that popliteal-sciatic perineural catheters placed via US guidance require less time for placement and produce equivalent results, as compared with catheters placed using ES. Methods: Preoperatively, subjects receiving a popliteal-sciatic perineural catheter for foot and/or ankle surgery were randomly assigned to either the ES with a stimulating catheter or US-guided technique with a nonstimulating catheter. The primary end point was catheter insertion duration (in minutes) starting when the US transducer (US group) or catheter-placement needle (ES group) first touched the patient and ending when the catheter-placement needle was removed after catheter insertion. Results: All US-guided catheters were placed per protocol (n = 20), whereas only 80% of stimulation-guided catheters could be placed per protocol (n = 20, P = 0.106). All catheters placed per protocol in both groups resulted in a successful surgical block. Perineural catheters placed by US took a median (10th-90th percentile) of 5.0 min (3.9-11.1 min) compared with 10.0 min (2.0-15.0 min) for stimulation (P = 0.034). Subjects in the US group experienced less pain during catheter placement, scoring discomfort a median of 0 (0.0-2.1) compared with 2.0 (0.0-5.0) for the stimulation group (P = 0.005) on a numeric rating scale of 0 to 10. Conclusions: Placement of popliteal-sciatic perineural catheters takes less time and produces less procedure-related discomfort when using US guidance compared with ES.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available