Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group: Considerations and pitfalls in commissioning and applicator reconstruction in 3D image-based treatment planning of cervix cancer brachytherapy

Journal

RADIOTHERAPY AND ONCOLOGY
Volume 96, Issue 2, Pages 153-160

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.radonc.2010.06.004

Keywords

3D brachytherapy; Applicator reconstruction; Commissioning

Funding

  1. Varian Medical Systems, Nucletron B.V.
  2. Isodose Control B.V
  3. Danish Cancer Society
  4. Danish Council for Strategic Research
  5. CIRRO - the Lundbeck Foundation Centre for Interventional Research in Radiation Oncology

Ask authors/readers for more resources

Image-guided brachytherapy in cervical cancer is increasingly replacing X-ray based close planning In image-guided brachytherapy the geometry of the applicator is extracted from the patient 3D images and introduced into the treatment planning system, a process referred to as applicator reconstruction Due to the steep brachytherapy dose gradients, reconstruction errors can lead to major dose deviations in target and organs at risk. Appropriate applicator commissioning and reconstruction methods must be implemented in order to minimise uncertainties and to avoid accidental errors Applicator commissioning verifies the location of source positions in relation to the applicator by using auto-radiography and imaging. Sectional imaging can be utilised in the process. with CT imaging being the optimal modality. The results from the commissioning process can be stored as library applicators The importance of proper commissioning is underlined by the fact that errors in library files result in systematic errors for clinical treatment plans. While the source channel is well visualised in CT images, applicator reconstruction is more challenging when using MR images. Availability of commercial dummy sources for MRI is limited, and image artifacts may occur with titanium applicators The choice of MR sequence is essential for optimal visualisation of the applicator. Para-transverse imaging (oriented according to the applicator) with small slice thickness (5 mm) is recommended or alternatively 3D MR sequences with isotropic voxel sizes Preferably, contouring and reconstruction should be performed in the same image series in order to avoid fusion uncertainties Clear and correct strategies for the applicator reconstruction will ensure that reconstruction uncertainties have limited impact on the delivered dose Under well-controlled circumstances the reconstruction uncertainties are in general smaller than other brachytherapy uncertainties such as contouring and organ movement. (C) 2010 Elsevier Ireland Ltd All rights reserved Radiotherapy and Oncology 96 (2010) 153-160

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available