Journal
RADIOPROTECTION
Volume 49, Issue 2, Pages 115-121Publisher
EDP SCIENCES S A
DOI: 10.1051/radiopro/2013090
Keywords
wax; plastic; polymer; effective atomic number; Compton scattering; Kerma
Ask authors/readers for more resources
We calculated mass attenuation coefficients, effective atomic numbers and Kerma relative to air for human organ and tissue substitutes (i.e. wax, plastic and polymer materials). The effective atomic numbers of the tissue substitutes were calculated by the direct method, interpolation method, Auto-Z(eff) software and single value XMuDat program and then compared. The calculated effective atomic numbers were also compared with available experimental data and a good agreement was observed. A large difference in effective atomic numbers calculated by the direct and interpolation methods was observed in photoelectric and pair-production regions. The direct method was found to be appropriate for effective atomic number computation in low-(>10 keV) and medium-(0.1 <= E <= 10 MeV) photon energy regions. Kerma relative to air of the selected tissue substitutes was found to be dependent upon the atomic number and element compositions, which show a sharp peak due to K-edge absorption.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available