4.0 Article

Assessment of methods for estimation of effective atomic numbers of common human organ and tissue substitutes: waxes, plastics and polymers

Journal

RADIOPROTECTION
Volume 49, Issue 2, Pages 115-121

Publisher

EDP SCIENCES S A
DOI: 10.1051/radiopro/2013090

Keywords

wax; plastic; polymer; effective atomic number; Compton scattering; Kerma

Ask authors/readers for more resources

We calculated mass attenuation coefficients, effective atomic numbers and Kerma relative to air for human organ and tissue substitutes (i.e. wax, plastic and polymer materials). The effective atomic numbers of the tissue substitutes were calculated by the direct method, interpolation method, Auto-Z(eff) software and single value XMuDat program and then compared. The calculated effective atomic numbers were also compared with available experimental data and a good agreement was observed. A large difference in effective atomic numbers calculated by the direct and interpolation methods was observed in photoelectric and pair-production regions. The direct method was found to be appropriate for effective atomic number computation in low-(>10 keV) and medium-(0.1 <= E <= 10 MeV) photon energy regions. Kerma relative to air of the selected tissue substitutes was found to be dependent upon the atomic number and element compositions, which show a sharp peak due to K-edge absorption.