4.7 Article

Computed Diffusion-weighted MR Imaging May Improve Tumor Detection

Journal

RADIOLOGY
Volume 261, Issue 2, Pages 573-581

Publisher

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.11101919

Keywords

-

Funding

  1. Cancer Research UK
  2. Engineering and Physical Sciences Research Council Cancer Imaging Centre
  3. MRC
  4. Department of Health (England) [C1060/A10334]
  5. NHS
  6. Engineering and Physical Sciences Research Council
  7. Medical Research Council [G0701533] Funding Source: researchfish
  8. MRC [G0701533] Funding Source: UKRI

Ask authors/readers for more resources

Purpose: To describe computed diffusion weighted (DW) magnetic resonance (MR) imaging as a method for obtaining high-value images from DW MR imaging performed at lower b values and to investigate the feasibility of the technique to improve lesion detection in oncologic cases. Materials and Methods: The study was approved by the institutional and research committee, and written informed consent was obtained from all patients. DW MR imaging was performed on a CuSO4 phantom at 1.5 T with a range of b values and compared with computed DW MR imaging images synthesized from lower b values (0 and 600 sec/mm(2)). The signal-to-noise ratio (SNR) was compared, and agreement between the SNR of computed DW MR imaging and theoretical estimation assessed. Computed DW MR imaging was evaluated in 10 oncologic patients who underwent whole-body DW MR imaging with b values of 0 and 900 sec/mm(2). Computed DW MR images at computed b values of 1500 and 2000 sec/mm(2) were generated. The image quality and background suppression of acquired and computed images were rated by a radiologist using a four-point scale. The diagnostic performance for malignant lesion detection using these images was evaluated and compared by using the McNemar Test. Results: The SNR of computed DW MR imaging of the phantom conformed closely to theoretical predictions. Computed DW MR imaging resulted in a higher SNR compared with acquired DW MR imaging, especially at b values greater than 840 sec/mm(2). In patients, images with a computed b value of 2000 sec/mm(2) produced good image quality and high background suppression (mean scores of 2.8 and 4.0, respectively). Evaluation of images with a computed b value of 2000 sec/mm(2) resulted in higher overall diagnostic sensitivity (96.0%) and specificity (96.6%) compared with images with an acquired b value of 900 sec/mm(2) (sensitivity, 89.4%; specificity, 87.5%; P < .01). Conclusion: Computed DW MR imaging in the body allows higher-b-value images to be obtained with a good SNR. Clinical computed DW MR imaging is feasible and may improve disease detection. (C) RSNA, 2011

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available