4.7 Article

Whole-Brain Perfusion CT Performed with a Prototype 256-Detector Row CT System: Initial Experience

Journal

RADIOLOGY
Volume 250, Issue 1, Pages 202-211

Publisher

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2501071809

Keywords

-

Funding

  1. Fujita Health University

Ask authors/readers for more resources

Purpose: To preliminarily evaluate the feasibility and potential diagnostic utility of whole-brain perfusion computed tomography (CT) performed with a prototype 256-detector row CT system over an extended range covering the entire brain to assess ischemic cerebrovascular disease. Materials and Methods: Institutional review board approval and informed consent were obtained. Eleven cases in 10 subjects (six men, four women; mean age, 64.3 years) with intra- or extracranial stenosis were retrospectively evaluated with whole-brain perfusion CT. Three readers independently evaluated perfusion CT data. The diagnostic performance of perfusion CT was visually evaluated with a three-point scale used to assess three factors. Differences between four axial perfusion CT images obtained at the basal ganglia level (hereafter, four-section images) and whole-brain perfusion CT images were assessed with the paired t test. In four subjects, the interval between perfusion CT and single photon emission computed tomography (SPECT) was 1-17 days (mean, 10.3 days). Correlation between perfusion CT findings and SPECT findings was assessed with the Spearman correlation coefficient. Results: Three-dimensional perfusion CT images and axial, coronal, and sagittal whole-brain perfusion CT images were displayed, and the extent of ischemia was assessed. Mean visual evaluation scores were significantly higher for whole-brain images than for four-section images (4.27 +/- 0.76 [standard deviation] vs 2.55 +/- 0.87). The cerebral blood flow ratios of the ischemic lesions relative to normal regions scanned with perfusion CT (x) and SPECT (y) showed a significant positive correlation (R-2 = 0.76, y = 0.44x + 0.37, P <.001). Conclusion: Perfusion CT performed with a 256-detector row CT system can be used to assess the entire brain with administration of one contrast medium bolus. Thus, ischemic regions can be identified with one examination, which has the potential to improve diagnostic utility. (C) RSNA, 2009

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available