4.6 Article

Design of high-performance adaptive objective lens with large optical depth scanning range for ultrabroad near infrared microscopic imaging

Journal

BIOMEDICAL OPTICS EXPRESS
Volume 6, Issue 9, Pages 3362-3377

Publisher

OPTICAL SOC AMER
DOI: 10.1364/BOE.6.003362

Keywords

-

Funding

  1. National Institutes of Health National Eye Institute, USA [R01 EY020641]
  2. National Institute of Biomedical Imaging and Bioengineering, USA [R21 EB008857]
  3. National Institute of General Medical Sciences, USA [R21 RR026254/R21GM103439]
  4. Wallace H. Coulter Foundation Career Award [WCF0086TN]

Ask authors/readers for more resources

We report on the theory and design of adaptive objective lens for ultra broadband near infrared light imaging with large dynamic optical depth scanning range by using an embedded tunable lens, which can find wide applications in deep tissue biomedical imaging systems, such as confocal microscope, optical coherence tomography (OCT), two-photon microscopy, etc., both in vivo and ex vivo. This design is based on, but not limited to, a home-made prototype of liquid-filled membrane lens with a clear aperture of 8mm and the thickness of 2.55mm similar to 3.18mm. It is beneficial to have an adaptive objective lens which allows an extended depth scanning range larger than the focal length zoom range, since this will keep the magnification of the whole system, numerical aperture (NA), field of view (FOV), and resolution more consistent. To achieve this goal, a systematic theory is presented, for the first time to our acknowledgment, by inserting the varifocal lens in between a front and a back solid lens group. The designed objective has a compact size (10mm-diameter and 15mm-length), ultrabroad working bandwidth (760nm - 920nm), a large depth scanning range (7.36mm in air) - 1.533 times of focal length zoom range (4.8mm in air), and a FOV around 1mm x 1mm. Diffraction-limited performance can be achieved within this ultrabroad bandwidth through all the scanning depth (the resolution is 2.22 mu m - 2.81 mu m, calculated at the wavelength of 800nm with the NA of 0.214 - 0.171). The chromatic focal shift value is within the depth of focus (field). The chromatic difference in distortion is nearly zero and the maximum distortion is less than 0.05%. (C) 2015 Optical Society of America

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available