4.7 Article

High-Temperature Solid-Media Thermal Energy Storage for Solar Thermal Power Plants

Journal

PROCEEDINGS OF THE IEEE
Volume 100, Issue 2, Pages 516-524

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JPROC.2011.2154290

Keywords

Concrete; parabolic trough power plant; sensible heat; thermal energy storage

Funding

  1. German Federal Ministry for the Environment, Nature Conservation, and Nuclear Safety [16UM0030, 16UM0023]
  2. ITES [03UM0064, 03UM0065]
  3. REAL-DISS [03UM0090]
  4. DE-TOP [0325164C]

Ask authors/readers for more resources

Solid sensible heat storage is an attractive option for high-temperature storage applications regarding investment and maintenance costs. Using concrete as solid storage material is most suitable, as it is easy to handle, the major aggregates are available all over the world, and there are no environmentally critical components. Long-term stability of concrete has been proven in oven experiments and through strength measurements up to 500 degrees C. Material parameters and storage performance have been validated in a 20-m(3) test module with more than 23 months of operation between 200 degrees C and 400 degrees C and more than 370 thermal cycles. For an up-scaled concrete storage design with 1100-MWh capacity in a modular setup for a 50 MWel parabolic trough power plant of the ANDASOL-type, about 50 000 m(3) of concrete is required and the investment costs are approximately 38 million euro. The simulation of the annual electricity generation of a 50 MWel parabolic trough power plant with a 1100-MWh concrete storage illustrates that such plants can operate in southern Europe delivering about 3500 full load hours annually; about 30% of this electricity would be generated by the storage system. This number will increase further, when improved operation strategies are applied. Approaches for further cost reduction using heat transfer structures with high thermal conductivity inside the concrete are analyzed, leading to a 60% reduction in the number of heat exchanger pipes required. For implementation of the structures, the storage is build up of precast concrete blocks.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available