4.6 Article

Scaling the flame transfer function of confined premixed conical flames

Journal

PROCEEDINGS OF THE COMBUSTION INSTITUTE
Volume 34, Issue -, Pages 1007-1014

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.proci.2012.06.056

Keywords

Flame dynamics; Confinement effects; Flame transfer function; Combustion instability

Funding

  1. European Community's Seventh Framework Program [ACP8-GA- 2009-234009]
  2. European initiative under the FP7

Ask authors/readers for more resources

The influence of confinement side walls on the response of premixed conical flames submitted to velocity disturbances is investigated experimentally and theoretically. When the flame is sufficiently confined, the burnt gases cannot fully expand at the nozzle outlet. In that case, the confinement ratio C-r = R-0/R-1 between the burner and flame tube radii and the burnt to unburnt gas volume expansion ratio E = rho(u)/rho(b) need to be taken into account in the description of the flame transfer function (FTF). The main effect of confinement is an acceleration of the fresh stream of reactants induced by the over-pressure of the confined burnt gases. Experiments on steady flames reveal that the flame height increases for increasing confinement ratios C-r, leading to a gain shift and a phase drop for the FTF. A theoretical analysis is conducted to model this acceleration and examine its impact on the steady flame shape and flame response to flow disturbances. The change in the FTF phase is shown to be related to a reduction of the mean time lag between heat release rate perturbations and velocity modulations induced by both the velocity acceleration in the fresh reactants and a change in the location of the steady flame front. An expression to scale the FTF of confined flames is derived based on a modification of the classical reduced frequency omega(*) used to scale the response of unconfined flames. This expression includes explicitly the confinement ratio C-r and the volume expansion ratio E. This new dimensionless number enables to plot FTF measured for different confinements with reasonable collapse. It may also be used to transpose FTF gathered on single burners to multiple injection configurations when the burnt gases cannot fully expand due to the presence of neighboring flames. (c) 2012 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available